...

neha.gaur@pahc.com

Approval StatusApproved
Access CodeeLAL4NaVvr
Legacy ID15375
Top Cards
Send Samples To:

Phibro-Tech Inc.

8851 Dice Road

Santa Fe Springs, CA 90670

A. General InformationA. General Information
Generator NameAC Zone 7 Water Agency
Generator Site Address901 E. Vineyards Ave
CityLivermore
STCA
Zip94550
Generator Mailing Address:100 N. Canyons Pkwy
CityLivermore
STCA
Zip94551
Phone No925-409-5027
Generator EPA ID NumberCAL000416405
Generator ContactDan Moy
Bill to CompanyEnvironmental Logistics, Inc
Bill to ContactChris Whitt
Bill to AddressPO Box 806
Email (notification sent to this email)Email hidden; Javascript is required.
B. Description of WasteB. Description of Waste
Generator's CommonGenerator's Common
Name of WasteFerric Chloride
Process Generating WasteTank Cleaning and Ferric Removal
C. Manifest and Labeling Information: C. Manifest and Labeling Information:
RQ
  • on
UN/NA No2582
Proper DOT Shipping Name

Waste Ferric Chloride Solution

Empty HTML Block

EPA Waste No
  • D002 Corrosive
State Waste No791 Liquids with pH ≤ 2
Haz Class8
PGIII
D. Characteristics of Waste: D. Characteristics of Waste:
ColorDark Brown
OdorMild
Flash PointCA
Physical State at 70 FMultilayered Liquid
pH1
Comments

CA

E. Select Generic Waste Type that best describes Waste Select Generic Waste Type that best describes Waste
Select Generic Waste Type that best describes WasteH (92) - Ferric Chloride, Ferrous Chloride or Hydrochloric Acid with iron
F. Metals Total PPM: E. Metals Total PPM:
%

%

Chemical Composition

(Please list all constituents in the material. Ranges are ok as long as they equal a minimum of 100%)

Percentage-138-42
Chemical-Composition-1Ferric Choride
Percentage-260-70
Chemical-Composition-2Other components below reportable levels
H. Anticipated Annual Volume: H. Anticipated Annual Volume:
Quantity3200
Quantity Optiononetime
Container Type (Select all that apply)
  • Bulk
I. Special Handling or Additional Information: I. Special Handling or Additional Information:
Phibro-Tech cannot process line

SAMPLE REQUIREMENT NOTICE: In accordance with Phibro-Tech’s RCRA Part B permit Waste Analysis Plan requirements, a representative sample of the waste stream must be submitted with all profiles for analysis. Samples should must be sent to: Phibro-Tech, Inc 8851 Dice Road, Santa Fe Springs, CA 90670, Attention: Customer Service

PFAS Screening

PFAS Screening

The Los Angeles County Sanitation District (LACSD) now requires Phibro-Tech, Inc to screen all waste streams for PFAS (Perfluoroalkyl and polyfluoroalkyl substances).

Specific waste streams identified by LACSD that require a PFAS analysis include:

  • Any amount of aqueous film forming foam (AFFF) such as fire-fighting water, fixed fire extinguishing system test water, and/or contaminated groundwater.
  • Process, rinse, and/or waste solutions containing hexavalent chromium (chrome VI or Cr(VI)) from chrome plating operations.
  • Any other waste streams that are known or suspected to contain excessive quantities of PFAS.

PFAS Question
Does this waste contain PFAS?
Does this waste fall into one of the above 3 categories?No
J. I hereby certifyI hereby certify that through generator knowledge and/or chemical analysis, all information submitted in this and all attached documents is complete, accurate, and that all known or suspected hazards have been disclosed. I also certify that the sample submitted with this document was collected using the appropriate sampling technique, so as to be representative of the actual stream. I also certify that the sample is properly classified, packaged, marked, and labeled and that the package is in proper condition for transportation according to DOT regulations. I also certify that this waste stream contains less than 10% organics and less than 500 parts per million (ppm) of volatile organic compounds (VOCs).
Authorized NameChris Whitt
TitleOperations Manager
Date2024/04/01
PDF Footer
Phibro Animal Health Corporation For further inquiries, contact PTIService@pahc.com
PDF Header
Phibro Animal Health Corporation

Corporate Office: Glenpointe Center East, 3rd Fl, 300 Frank W. Burr Blvd Ste 21, Teaneck, NJ 07666-6712 · (201) 329-7300

SEND SAMPLES TO: Phibro-Tech, Inc. 8851 Dice Road Santa Fe Springs, California 90670 · (800) 777-1850

PDF Content

Date: {TD}



Dear Customer,



Congratulations, the following profile has been approved for recycling at Phibro-Tech, Inc. under our Environmental Recovery Service (ERS). We appreciate the opportunity to manage this material for you.




  • Generator Name: {GeneratorName}

  • Waste Name: {WasteName}

  • ERS (Profile) Number: {ERS}

  • Expiration Date: {ExpirationDate}

  • Price Code: {PriceCode}



The following pricing will apply
{Pricing}



Standard Pricing Rules:

  • 1) Resource & Recovery Fee of 20% applied to every billable order.

  • 2) All Disposal pricing is FOB Phibro-Tech Inc., 8851 Dice Rd. Santa Fe Springs, CA. 90670.

  • 3) Non standard container sizes are billed as special pricing.

  • 4) Profiles are priced at the time of profile approval.

  • 5) Pricing to be reviewed at profile renewal.

  • 6) All disposal is via Wastewater Treatment unless otherwise specified.

  • 7) $100 minimum fee per manifest.

  • 8) $35 Manifest fee per manifest.

  • 9) IBC's with < 225 gallons will be billed at 225 gallons.

  • 10) $50 surcharge per non-conforming container including totes, overpacks, and broken pallets.

  • 11) $15 per drum if not on pallets.

  • 12) $400 per drum for offsite disposal of drums with solids.

  • 13) $100 surcharge for IBC’s with significant solids.

  • 14) $100 per labor hour per person for non-standard waste off-loading work.

  • 15) $250 fee for unscheduled loads, no show for scheduled or reoccurring loads, or same day cancellation.

  • 16) $250 Emergency profile fee for new or expired wastes that need to be sampled on arrival.

  • 17) Safety Surcharge for high risk waste streams requiring extra handling or waste streams with free chlorine: Bulk $4,000 /Tote $1,000. Drums based on tiered sizes largest to smallest: $400/$300 /$200 /$100

  • 18) Spent ammonia and cupric non-conforming charge: $1.00/gallon Nickel > 50 PPM or Iron > 200 ppm.

  • 19) $250 for weekend scheduling based on PTI availability.




PHIBRO-TECH, INC HAS THE APPROPRIATE PERMIT(S) FOR, AND WILL ACCEPT, THE HAZARDOUS WASTE APPROVED UNDER THIS PROFILE.